Leírás
Operating Flexibility
- Operating modes can be programmed flexibly
- On-grid operating, easy feed-in to the grid, backflow prevention, energy self-generation and self-consumption.
- Off-grid operating, no worry about grid power failure
- Solar power, battery power and AC utility power source to provide loads with continuous power
- Even with grid or PV input only, inverter can still start working without battery
- Priority of PV, battery or grid power source can be programmed flexibly
- High efficiency of battery management system, EOD, floating voltage and charge current are settable.
High efficiency and safety
- Soft-switching technology, inproving inverter efficiency
- DSP complete digital control technology
- Small size, light weight, easy installation
- Superior protection
Intelligent monitoring
- LCD, LED display real-time operating information
- Monitoring software display real-time operating information
- Monitoring software make operating modes programmed and control
●Various communications selectable via USB, RS232, RS485, SNMP
| Rated power | 3000 W | 
| Operating mode | Flexible setup via upper computer software or LCD interface | 
| PV INPUT | |
| Max. input power | 4500 W | 
| Rated input voltage | 360 Vdc | 
| Max. input voltage | 500 Vdc | 
| Start-up voltage | 115 Vdc | 
| Initial feeding voltage | 150 Vdc | 
| MPPT voltage range | 250 Vdc ~ 450 Vdc | 
| Max. input current | 18 A | 
| PV short circuit current | 18 A | 
| Number of MPPT | 1 | 
| BATTERIES | |
| Battery type | Lithium battery | 
| Rated voltage | 51.2 Vdc | 
| Voltage range | 46.4 Vdc ~ 57.6 Vdc | 
| Battery type | VRLA AGM maintenance-free battery | 
| Rated voltage | 48 Vdc | 
| Voltage range | 40 Vdc ~ 58 Vdc | 
| Battery capacity | 100 Ah ~ 120 Ah optimized | 
| Rated charger power | 1425 W | 
| Max. charging current | 25 A (5 A / 10 A / 15 A / 20 A / 25 A settable) | 
| Charging curve | 3-Stage | 
| Max. charging efficiency | 94% | 
| Rated discharge power | 3000 W | 
| Max. discharge current | 100 A | 
| Discharge depth(%) | 80% default | 
| Max. discharge efficiency | 94% | 
| AC GRID INPUT | |
| AC start-up voltage | 120 Vac | 
| Grid voltage range | 170 ~ 280 Vac | 
| Rated grid frequency | 50 Hz / 60 Hz | 
| Allowed grid frequency | 50 ± 5 Hz / 60 ± 5 Hz | 
| AC input power | 5100 VA / 5100 W | 
| Max. input current | 30 A | 
| AC OUTPUT (connect with load) | |
| Rated output power | 3000 VA / 3000 W | 
| Rated output voltage | 230 Vac(208 / 220 / 240Vac settable) | 
| Rated output current | 13.0 A (14.4 A / 13.6 A / 12.5 A) | 
| Output voltage range | 184 Vac ~ 264.5 Vac | 
| Rated output frequency | 50 Hz / 60 Hz | 
| Output frequency precision | ± 1% | 
| Power factor | 0.9 leading ~ 0.9 lagging | 
| Output voltage precision | ± 1% | 
| Transient recovery time | ≤ 40ms | 
| Peak factor | 3 : 1 | 
| Linear load waveform | ≤ 3% | 
| Short circuit current | 45 A (100 ms) | 
| TRANSFER TIME | |
| Off-grid mode → On-grid mode | 0 ms | 
| On-grid mode → Off-grid mode | 10 ms | 
| EFFICIENCY | |
| MPPT efficiency | 99% | 
| Max. PV efficiency | 96% | 
| OTHERS | |
| Dimensions(W×H×D)(mm) | 410 ×470 ×123 | 
| Weight (kg) | 14 | 
| Communications | RS232 / USB / RS485 / SNMP (optional) | 
| Protection rating | IP20 | 
| Operating temperature | 0 ~ 40℃(> 40℃ derating) | 
| Max. relative humidity | 0 ~ 90% | 
| Max. altitude | < 1000 m (> 1000 m derating) | 
| Cooling | forced ventilation | 
| Alarm | LED, buzzer | 
| Display | LED, LCD | 
| Noise | ≤ 50 dB | 
| Topology | Transformerless | 








Értékelések