Leírás
| V2G Split-type Bi-direction Charging Equipment | 
| According to energy storage power station, interactive smart grid and optimized using of energy resources, EAST developed the new generation of power products, being as bi-direction converter of AC DC, DC AC linked to public power grid in energy storage, photovoltaic, micro network system. Split-type charger consists of bi-direction rectifier cabinet and outdoor charging sets, using modular design, single rectifier module and inverter module being 50kw. It is applicable to charging stations and enterprises’ parking lot. Split-type public DC charger I: Output voltage range DC 250 V ~ 750 V adjustable, the maximum output power of single unit is 50KW. Split-type public DC charger II: Output voltage range DC 250 V ~ 750 V adjustable, the maximum output power of single unit is 150KW | 
● It consists of IGBT converter devices, AC / DC filter devices, soft starter, monitor, isolation transformers and protection devices etc.
● It is featured with power grid peak regulations, improving power grid quality, new energy access and other functions.
| MODEL | EVDC-50KW-V | EVDC-150KW-V | 
| INPUT | ||
| Input voltage | 260 V ~ 456 V (three phase five wire) | |
| Input current | ≤ 300 A | |
| AC Input frequency | 45 Hz ~ 65 Hz | |
| Efficiency | ||
| Power factor | ≥ 0.99 | |
| Input THD | ≤ 5% | |
| DC OUTPUT | ||
| Output voltage range | 700 Vdc series:250 V ~750 V | |
| Rated output current | 80 A | 240 A | 
| Max. output current | 85 A | 250 A | 
| Soft start time | 3 s ~ 8 s | |
| Output constant-current range | 10% ~ 100% | |
| Voltage regulation accuracy | ≤ ± 0.5% | |
| Current regulation accuracy | ≤ ± 0.5% | |
| Ripple coefficient (peak value) | ≤ 1% | |
| Current-sharing unbalanced degree | ≤ ± 5% (10% ~ 100% rated load) | |
| Noise | < 55 dB | |
| INVERTER OUTPUT | ||
| Output voltage range | 400 V ± 15% (three phase three wire) | |
| Max. efficiency | ≥ 93% | |
| Allowable grid frequency | 47 Hz ~ 51.5 Hz | |
| Power factor | ≥ 0.99 | |
| Output THD | ≤ 5% | |
| THDi | < 3% (rated power) | |
| Power factor | 0.9 (leading) – 0.9 (lagging) | |
| PROTECTIONS | ||
| Output short-circuit protection | Retraction current ≤ 40% Io; auto-restorable | |
| Output overvoltage protection | No output after protection; | |
| Input over / under voltage protection | No output after protection; auto-restorable | |
| Phase-lack protection | No output after protection; auto-restorable | |
| Overtemperature protection | No output after protection; auto-restorable | |
| CHARGING CONFIGURATION AND STANDARD | ||
| Charging plug number | / | |
| Charging cable length (m) | / | |
| Communication protocol standard | GB/T 27930-2015 | |
| Charger standard | GB/T 18487.1-2015, GB/T 20234.1-2015, GB/T 20234.3-2015, NB/T 33001-2010, NB/T 33008.1-2013 | |
| OTHERS | ||
| Operating temperature | -20℃ ~ + 50℃ | |
| Storage temperature | -40℃ ~ + 80℃ | |
| Relative humidity | ≤ 95% | |
| Atmospheric pressure | 70 kPa ~ 106 kPa | |
| IP rating | IP31 | |
| Dimensions (H*W*D) (mm) | 2000*600*600 | 2000*1200*800 | 
| Weight (kg) | ≤ 620 | ≤ 1500 | 








Értékelések